Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Braz. j. oral sci ; 22: e231137, Jan.-Dec. 2023. ilus
Article in English | LILACS, BBO | ID: biblio-1523140

ABSTRACT

The purpose of this in vitro study was to analyze the influence of nicotine on the extracellular polysaccharides in Fusobacterium nucleatum biofilm. Methods: F. nucleatum (ATCC 10953) biofilms supplemented with different concentrations of nicotine (0, 0.5, 1, 2, 4, and 8 mg/mL) were grown in two different BHI broth conditions [no sucrose and 1% sucrose]. Extracellular polysaccharides assay, pH measurements, and a spectrophotometric assay were performed. Data were submitted for ANOVA and Tukey honestly significant difference analyses (HSD) tests (α =.05). Results: Extracellular polysaccharides synthesis was influenced by an interaction between nicotine concentrations and growth medium solution containing sucrose (P<.05). The pH values declined in the sucrose-exposed biofilm were greater than in the group exposed only to nicotine (P<.05). The biofilm exposed to sucrose and nicotine had a higher total biofilm growth (P<.05) than the nicotine-treated biofilm without sucrose. Conclusions: Regardless of sucrose exposure, biofilms exposed to different nicotine concentrations influenced the amount of extracellular polysaccharides


Subject(s)
Humans , Polysaccharides, Bacterial/chemical synthesis , Fusobacterium nucleatum/growth & development , Biofilms/growth & development , Nicotine/pharmacology , Periodontal Diseases/microbiology , Spectrophotometry , Sucrose/administration & dosage , Culture Media , Dental Caries/microbiology , Nicotine/administration & dosage
2.
Braz. oral res. (Online) ; 37: e047, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1439732

ABSTRACT

Abstract To evaluate the feasibility of using a milled polyetheretherketone (PEEK) post and core in endodontically treated teeth with or without a ferrule. Sixty bovine tooth roots were endodontically treated followed by cementation of intraradicular retainers (IR), according to each experimental group: a) non-ferrule glass fiber post (f0FP); b) 2-mm-ferrule glass fiber post (f2FP); c) non-ferrule resized glass fiber post (f0PR); d) 2-mm-ferrule resized glass fiber post (f2PR); e) non-ferrule PEEK post and core (f0PPC); and f) 2-mm-ferrule PEEK post and core (f2PPC). Metal crowns were made and cemented. A periodontal ligament was simulated using polyether. A force was applied to the palatine portion of each sample at 45°, until fracture. Fracture resistance data were submitted to two-way ANOVA and Tukey's test (α = 0.05). Three-dimensional digital models were developed to calculate the tensions formed in the root using finite element analysis. Models of glass fiber posts and PEEK posts and cores were evaluated with or without a ferrule. The results were analyzed by the Mohr-Coulomb criterion. The type of IR was not influenced by fracture strength (p = 0.243). There were significant statistical differences among the remaining factors. Ferrule groups had greater fracture resistance, and the failure mode of teeth with a ferrule was more catastrophic than the non-ferrule group. A ferrule increases fracture resistance and influences failure mode; the PEEK post and core did not modify the biomechanics of endodontically treated teeth, and resembled the glass fiber post results. The crack initiation point differed between the ferrule and non-ferrule groups.

3.
Braz. oral res. (Online) ; 36: e011, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO | ID: biblio-1355932

ABSTRACT

Abstract Mucopolysaccharidosis (MPS) is a heterogeneous group of rare, chronic, progressive and systemic inherited disorders resulting from deficiency or lack of lysosomal enzymes responsible for the degradation of glycosaminoglycans. Products of nitrosative stress have been previously detected in blood and urine samples of patients with MPS. However, it is unclear whether they are present in the saliva of MPS patients and also if they correlate with salivary parameters such as flow and pH. This study compared the salivary levels of NOX (NO2- + NO3-), nitrite (NO2-), protein (albumin), erythrocyte and leukocyte numbers, as well as the salivary flow rate and pH values of samples obtained from 10 MPS patients and 10 healthy subjects. MPS patients exhibited higher salivary levels of NOX and NO2- when compared to healthy subjects (p < 0.05). Albumin was only detected in six saliva samples of MPS patients and, erythrocytes and leukocytes were detected in 60% and 40% of the MPS patients, respectively. In addition, salivary flow rate and pH averages were statistically lower in this group when compared to healthy samples (p < 0.05). Overall, the data indicates that the salivary levels of NO products can be used in combination with other heath indicators to monitor MPS disorders.

4.
Braz. dent. j ; 32(2): 64-71, Mar.-Apr. 2021. tab, graf
Article in English | LILACS, BBO | ID: biblio-1339323

ABSTRACT

Abstract This study evaluated the dental displacement in dentures included in different flasks and processed by the Australian cycle modified or by microwave. Metal pins were placed on the teeth as reference for measurements: a) Incisal edge of maxillary and mandibular central incisors, buccal cusp of maxillary and mandibular vestibular first premolars, and mesiobuccal maxillary and mandibular cusps of second molars; b) Incisor to incisor, premolar to premolar and molar to molar; c) Left incisor to left molar and right incisor to right molar, and d) Vertical. Dentures were divided according to flasks (n=10): G1- Metal; G2- HH bimaxillary metal; G3-Microwaves; G4- HH bimaxillary microwaves. For G1 and G2, polymerization at 65ºC/30 min, flame quenched for 30 min, heating at 65ºC/30 min, boiling water for 1 h. For G3 and G4, microwave (20 min/140 W and 5 min/560 W). Comparator microscope with digital camera and analytical unit assessed the measurements before and after denture polymerization. The final distance was made subtracting the distance before the denture processing from the distance of the dental displacement after processing. The value of the difference was submitted to 2-way ANOVA, considering the flask type and denture type. Maxillary denture showed greater displacement when compared to mandibular denture. Flask types and interaction with denture types showed similar difference between before and after polymerization. In conclusion, displacement promoted by flask types in dentures cured by polymerization cycles promoted similar effect on the distance between teeth. Greater value for distance between teeth occurred for maxillary denture.


Resumo O objetivo neste estudo foi avaliar o deslocamento dental em próteses totais incluídas em diferentes tipos de muflas e polimerizadas pelo ciclo australiano ou por micro ondas. Pinos metálicos foram colocados nos dentes como pontos de referência para as medidas: a) Borda incisal dos incisivos centrais maxilares e mandibulares, cúspide vestibular dos primeiros pré molares maxilares e mandibulares e cúspides mésiovestibulares dos segundos molares maxilares e mandibulares; b) Distâncias látero-laterais incisivo a incisivo, pré-molar a pré-molar e molar a molar; c) Distâncias horizontais anteroposterior incisivo esquerdo a molar esquerdo e incisivo direito a molar direito, e d) Vertical. As próteses foram separadas de acordo com o tipo de mufla (n=20): G1- Metálica; G2-HH bi-maxilar metálica; G3- Micro-ondas; G4- HH bi-maxilar micro ondas. Ciclo de polimerização para G1 e G2, água a 65ºC por 30 minutos, aquecimento interrompido por 30 minutos, reaquecimento a 65ºC por 30 minutos, seguido de água fervente por 1 hora. Para G3 e G4, micro ondas (20 minutos a 140 W e 5 minutos a 560 W). As medidas foram avaliadas com microscópio comparador linear. A distância final entre os dentes foi obtida subtraindo o valor da distância antes do processamento da prótese do valor da distância resultante do deslocamento dentário após o processamento. A diferença obtida entre essas distâncias foi submetida à ANOVA de 2 fatores, considerando como variáveis tipo de mufla e tipo de prótese. A prótese maxilar apresentou maior deslocamento dental quando comparada à mandibular. Os tipos de muflas e a interação com os tipos de próteses mostraram movimentos dentais similares antes e depois da polimerização. Em conclusão, o deslocamento dental promovido por diferentes tipos de frascos em próteses curadas por diferentes ciclos de polimerização promoveu efeito semelhante na alteração da distância entre os dentes. Maior valor para a mudança de distância entre os dentes ocorreu na prótese maxilar.


Subject(s)
Denture, Complete , Australia , Polymerization
5.
Rev. cir. traumatol. buco-maxilo-fac ; 19(4): 5-6, out.-dez. 2019.
Article in Portuguese | BBO, LILACS | ID: biblio-1253604
6.
Braz. j. oral sci ; 17: e181097, 2018. ilus
Article in English | LILACS, BBO | ID: biblio-963829

ABSTRACT

Aim: To compare the reliability between photoelastic and finite element (FE) analyses by evaluating the effect of different marginal misfit levels on the stresses generated on two different implant-supported systems using conventional and short implants. Methods: Two photoelastic models were obtained: model C with two conventional implants (4.1×11 mm); and model S with a conventional and a short implant (5×6 mm). Three-unit CoCr frameworks were fabricated simulating a superior first pre-molar (P) to first molar (M) fixed dental prosthesis. Different levels of misfit (µm) were selected based on the misfit average of 10 frameworks obtained by the single-screw test protocol: low (<20), medium (>20 and <40) and high (>40). Stress levels and distribution were measured by photoelastic analysis. A similar situation of the in vitro assay was designed and simulated by the in silico analysis. Maximum and minimum principal strain were recorded numerically and color-coded for the models. Von Mises Stress was obtained for the metallic components. Results: Photoelasticity and FE analyses showed similar tendency where the increase of misfit generates higher stress levels despite of the implant design. The short implant showed lower von Mises stress values; however, it presented stresses around its full length for the in vitro and in silico analysis. Also, model S showed higher µstrain values for all simulated misfit levels. The type of implant did not affect the stresses around pillar P. Conclusions: Photoelasticity and FEA are reliable methodologies presenting similarity for the investigation of the biomechanical behavior of implant-supported rehabilitations


Subject(s)
Biomechanical Phenomena , Dental Implants , Finite Element Analysis , Optical Phenomena
7.
In. Miyashita, Eduardo; Pellizzer, Eduardo Piza; Kimpara, Estevão Tomomitsu. Reabilitação oral contemporânea baseada em evidências científicas. Nova Odessa, Napoleão editora, jun. 2014. p.424-467, ilus. (BR).
Monography in Portuguese | LILACS, BBO | ID: lil-715172
8.
Odonto (Säo Bernardo do Campo) ; 19(37): 39-47, jan.-jun.2011.
Article in Portuguese | LILACS | ID: lil-789949

ABSTRACT

O aumento da idade tem uma importante influência na prevalência de doenças bucais, já que a mucosa oral torna-se mais sensível aos danos mecânicos. O surgimento e o desenvolvimento de grande parte das doenças que se manifestam na cavidade bucal na velhice, revelam a interação existente entre as alterações degenerativas da idade e condições patológicas. É preciso esclarecer que as modificações ocorridas nos tecidos bucais não se resumem às perdas parcial ou total dos dentes. As modificações sofridas pelos tecidos moles da boca são pouco estudadas na literatura e, por serem de grande freqüência, necessitam de conhecimentos mais aprofundados, de modo a fornecerem subsídios e contribuírem para o aprimoramento deste campo da Odontologia.Objetivo: este estudo teve como propósito fazer um levantamento na literatura para verificar as principais alterações e lesões bucais que acometem o idoso.Conclusão: pôde-se observar que o paciente geriátrico está sujeito a uma variedade de lesões, como as iatrogênicas causadas por próteses mal adaptadas, as diversas lesões benignas e as cancerizáveis. Dessa forma, o cirurgião dentista tem papel fundamental na detecção de qualquer anormalidade que o idoso apresenta na cavidade bucal, e o diagnóstico precoce possibilita um tratamento mais conservador...


The aging has an important influence on the prevalence of oral diseases since the oral mucosa becomes more sensitive to the mechanical damages. Most of the diseases in oral cavity of elderly people are related to the interaction of degenerative alterations and pathological conditions. It is important to clarify that the modifications of the elderly’s oral environment are not only regarded to partial and total teeth loss. The understanding of alterations of soft tissues in elderly people remains unclear in literature.Aim: therefore, the purpose of the present literature review was to verify the principal alterations and oral lesions that affect aging patients.Conclusion: several different lesions affect the elderly people such as iatrogenic lesion caused by poor fit complete denture as well as begnin and carcinogen lesions. Therefore, the dental surgeon has the important role for diagnosis of abnormalities in the oral cavity of elderly patient and to perform an early diagnosis to provide a conservative treatment...


Subject(s)
Humans , Aged , Aged, 80 and over , Mouth Diseases/etiology , Mouth Diseases/pathology , Geriatric Dentistry , Health of the Elderly , Oral Health
9.
Araçatuba; s.n; 2011. 245 p. ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-710782

ABSTRACT

Objetivos: (1) Investigar o papel de diferentes níveis de pH da saliva artificial (3; 6,5 e 9) no comportamento corrosivo do titânio comercialmente puro (cp-Ti) e da liga Ti-6Al-4V (Capítulo 1); (2) Avaliar a influência do processo de corrosão na afinidade do lipopolissacarídeo (LPS) de Escherichia coli para o cp-Ti e o Ti-6Al-4V (Capítulo 2); (3) Investigar a natureza tribocorrosiva do titânio em saliva artificial em presença de LPS (Capítulo 3); (4) Comparar o efeito de diferentes designs de overdentures implanto-retidas e prótese total fixa implanto-suportada na distribuição de tensões em mandíbula edêntula pelo método de elementos finitos tridimensional (Capítulo 4). Materiais e métodos: Testes eletroquímicos como potencial de circuito aberto, espectroscopia de impedância eletroquímica, e teste potenciodinâmico foram conduzidos. Para o teste de afinidade ao LPS, os espécimes foram tratados com LPS (1,5; 15 e 150 μg/ml) durante 24 horas para avaliar a aderência de LPS. Os discos foram transferidos a cada 24 horas para solução fresca de água livre de LPS até completar 72 horas, para investigar a liberação de LPS. No teste de tribocorrosão, o pH da saliva (6,5), a concentração de LPS (0, 0,15, 15 and 150 μg/ml), a duração do deslizamento (2000 ciclos), freqüência (1,2 Hz) e carga (20 N) foram usados para mimetizar o processo mastigatório. Finalmente, modelos tridimensionais de uma mandíbula edêntula foram construídos. No grupo OR a mandíbula foi restaurada com overdenture retida por implantes não esplitados com sistema de retenção O’ring; nos grupos BC-C e BC as mandíbulas foram restauradas com overdentures retidas por implantes esplintados com sistema de retenção barra-clipe associado ou não a cantilevers distais, respectivamente; no grupo FD a mandíbula foi restaurada com prótese total fixa suportada por implantes. As tensões de von Mises (σvM), máxima (σmax) e mínima (σmin) tensões principais foram obtidas. Resultados: A saliva ácida aumentou a taxa de...


Objectives: (1) To investigate the role of different levels of pH of artificial saliva (pHs 3, 6.5 and 9) under simulated oral environment on the corrosion behavior of commercially-pure titanium (cp-Ti) and Ti-6Al-4V alloy (Chapter 1); (2) To assess the influence of corrosion process on Escherichia coli lipopolysaccharide (LPS) affinity for cp-Ti and Ti-6Al-4V alloy (Chapter 2); (3) To evaluate the tribocorrosive (corrosion/wear) nature of titanium in artificial saliva (pH 6.5) with LPS (Chapter 3); and (4) To compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible by using a three-dimensional finite element analysis. Materials and methods: Standard electrochemical tests, such as open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic tests were conducted in a controlled environment. For LPS affinity test, specimens were treated with LPS (1.5, 15 and 150 μg/ml) for 24 hours to evaluated LPS adherence. Discs were then transferred every 24 hours to fresh LPS-free water, up to 72 hours, to investigate LPS elution. In the tribocorrosion test, the pH of saliva (6.5); LPS concentration (0, 0.15, 15 and 150 μg/ml), sliding duration (2000 cycles), frequency (1.2Hz) and load (20 N) parameters mimicked the mastication process. Finally, tridimensional models of an edentulous mandible were constructed. In the OR group, the mandible was restored with an overdenture retained by unsplinted implants with O’ring attachment; in the BC-C and BC groups, the mandibles were restored with overdentures retained by splinted implants with bar-clip anchor associated or not with distally placed cantilevers, respectively; in the FD group, the mandible was restored with a fixed full-arch implant-supported prosthesis. The von Mises stress (σvM), the maximum (σmax) and minimum (σmin) principal stresses were obtained. Results: Acidic saliva increased the…


Subject(s)
Dental Implantation , Titanium , Biomechanical Phenomena , Electrochemistry , Finite Element Analysis
10.
Araçatuba; s.n; 2011. 245 p. ilus, graf.
Thesis in Portuguese | LILACS, BBO | ID: lil-705161

ABSTRACT

Objetivos: (1) Investigar o papel de diferentes níveis de pH da saliva artificial (3; 6,5 e 9) no comportamento corrosivo do titânio comercialmente puro (cp-Ti) e da liga Ti-6Al-4V (Capítulo 1); (2) Avaliar a influência do processo de corrosão na afinidade do lipopolissacarídeo (LPS) de Escherichia coli para o cp-Ti e o Ti-6Al-4V (Capítulo 2); (3) Investigar a natureza tribocorrosiva do titânio em saliva artificial em presença de LPS (Capítulo 3); (4) Comparar o efeito de diferentes designs de overdentures implanto-retidas e prótese total fixa implanto-suportada na distribuição de tensões em mandíbula edêntula pelo método de elementos finitos tridimensional (Capítulo 4). Materiais e métodos: Testes eletroquímicos como potencial de circuito aberto, espectroscopia de impedância eletroquímica, e teste potenciodinâmico foram conduzidos. Para o teste de afinidade ao LPS, os espécimes foram tratados com LPS (1,5; 15 e 150 μg/ml) durante 24 horas para avaliar a aderência de LPS. Os discos foram transferidos a cada 24 horas para solução fresca de água livre de LPS até completar 72 horas, para investigar a liberação de LPS. No teste de tribocorrosão, o pH da saliva (6,5), a concentração de LPS (0, 0,15, 15 and 150 μg/ml), a duração do deslizamento (2000 ciclos), freqüência (1,2 Hz) e carga (20 N) foram usados para mimetizar o processo mastigatório. Finalmente, modelos tridimensionais de uma mandíbula edêntula foram construídos. No grupo OR a mandíbula foi restaurada com overdenture retida por implantes não esplitados com sistema de retenção O’ring; nos grupos BC-C e BC as mandíbulas foram restauradas com overdentures retidas por implantes esplintados com sistema de retenção barra-clipe associado ou não a cantilevers distais, respectivamente; no grupo FD a mandíbula foi restaurada com prótese total fixa suportada por implantes. As tensões de von Mises (σvM), máxima (σmax) e mínima (σmin) tensões principais foram obtidas. Resultados: A saliva ácida aumentou a taxa de...


Objectives: (1) To investigate the role of different levels of pH of artificial saliva (pHs 3, 6.5 and 9) under simulated oral environment on the corrosion behavior of commercially-pure titanium (cp-Ti) and Ti-6Al-4V alloy (Chapter 1); (2) To assess the influence of corrosion process on Escherichia coli lipopolysaccharide (LPS) affinity for cp-Ti and Ti-6Al-4V alloy (Chapter 2); (3) To evaluate the tribocorrosive (corrosion/wear) nature of titanium in artificial saliva (pH 6.5) with LPS (Chapter 3); and (4) To compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible by using a three-dimensional finite element analysis. Materials and methods: Standard electrochemical tests, such as open circuit potential, electrochemical impedance spectroscopy, and potentiodynamic tests were conducted in a controlled environment. For LPS affinity test, specimens were treated with LPS (1.5, 15 and 150 μg/ml) for 24 hours to evaluated LPS adherence. Discs were then transferred every 24 hours to fresh LPS-free water, up to 72 hours, to investigate LPS elution. In the tribocorrosion test, the pH of saliva (6.5); LPS concentration (0, 0.15, 15 and 150 μg/ml), sliding duration (2000 cycles), frequency (1.2Hz) and load (20 N) parameters mimicked the mastication process. Finally, tridimensional models of an edentulous mandible were constructed. In the OR group, the mandible was restored with an overdenture retained by unsplinted implants with O’ring attachment; in the BC-C and BC groups, the mandibles were restored with overdentures retained by splinted implants with bar-clip anchor associated or not with distally placed cantilevers, respectively; in the FD group, the mandible was restored with a fixed full-arch implant-supported prosthesis. The von Mises stress (σvM), the maximum (σmax) and minimum (σmin) principal stresses were obtained. Results: Acidic saliva increased the…


Subject(s)
Dental Implantation , Titanium , Biomechanical Phenomena , Electrochemistry , Finite Element Analysis
11.
ImplantNews ; 7(4): 548-552, 2010.
Article in Portuguese | LILACS, BBO | ID: lil-564692

ABSTRACT

A reabilitação de indivíduos totalmente desdentados, desde os primordios conceitos e fundamentos da reabilitação oclusal, tem sido um grande desafio para os profissionais da Odontologia. Porém, essa filosofia tornou-se otimizada pelas próteses totais fixas implantossuportadas, denominadas próteses protocolo, representando uma modalidade clinicamente previsível no âmbito da Odontologia moderna. Contudo, esse protocolo terapêutico tradicional requer um tempo de cicatrização óssea e consequente reabilitação prolongados, o que fundamentou a proposta do carregamento imediato dos implantes, que apresenta como vantagem principal a reabilitação funcional e estética dos pacientes em um período significativamente diminuto. O propósito do presente artigo é discutir, baseado na literatura contemporânea, os fundamentos biomecânicos e funcionais de oclusão aplicados às próteses do tipo protocolo com carregamento mediato e imediato, proporcionando evidências clínicas que visem à longevidade das reabilitações orais envolvidas nessa modalidade terapêutica. Pré-requisitos como: boa qualidade óssea, excelente estabilidade primária, adequado número de implantes, esplintagem rígida e, principalmente, o controle e o domínio dos fundamentos biomecânicos da oclusão estática e dinâmica são imprescindíveis para a previsibilidade e longevidade desses tratamentos.


Rehabilitation of edentulous patients has been a challenge for professionals since the primary concepts and fundaments of occlusal rehabilitation. However, this philosophy has been improved by implant-supported fixed dentures that represent a predictable clinical modality on modern dentistry. Nevertheless, considering that the traditional protocol requires a long period for bone healing and definitive rehabilitation, immediate loading of implants has been advantageous for functional and esthetic rehabilitation of patients in a reduced period. The aim of this study is to discuss the biomechanical and functional fundaments of occlusion for implant-supported fixed dentures with mediate and immediate loading to provide clinical evidences for longevity of this treat ment modality based on the current literature. According to this, some prerequisites as proper bone quality, excellent primary stability, sufficient number of implants, rigid splinting, and control and mastering of biomechanical fundamentals of static and dynamic occlusion are mandatory for treatment predictability and longevity.


Subject(s)
Dental Implants , Dental Occlusion , Dental Prosthesis, Implant-Supported , Biomechanical Phenomena
12.
Pesqui. bras. odontopediatria clín. integr ; 8(2): 251-257, maio-ago. 2008. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-873636

ABSTRACT

Introdução: Nas situações de grandes reabsorções dos rebordosalveolares, ficam mais evidentes as relações que os músculosorofaciais determinam sobre a região do osso basal, salientandoseos efeitos que a ação contrátil de suas fibras produzem sobreas diversas zonas de contorno. Dessa forma, a prótese total deveestar bem adaptada à área basal, respeitando as estruturasanatômicas envolvidas direta ou indiretamente.Objetivo: Realizar uma revisão da literatura sobre a inter-relaçãoentre anatomia e prótese total, enfocando a ação da musculaturaparaprotética sobre essas próteses, além de avaliar os principaisrequisitos para a obtenção de estabilidade e retenção das mesmas.Método: Foram utilizados os indexadores OldMedline e Medlinedatabase entre o período de 1942 e 2007, com o cruzamento dostermos complete denture, anatomy e stability. O indexador BBOtambém foi utilizado, com os termos prótese total e anatomia, noperíodo de 1985 a 2007. Foi realizada a leitura do título e do resumodos artigos, e trabalhos que não mostravam a relação existenteentre estruturas anatômicas e prótese total foram excluídos. Dessaforma, dos 78 artigos obtidos na pesquisa inicial, 30 foramselecionados. Livros nacionais e internacionais também foramconsultados.Conclusão: Através dos dados disponíveis na literatura, pode-seobservar que muitas estruturas anatômicas orofaciais apresentamrelação direta com as próteses totais, de forma que essas estruturaspodem afetar a estabilidade, retenção e características funcionaisdas próteses. Por isso, é importante não somente reconhecer asestruturas paraprotéticas, mas também, saber identificar qual afunção que desempenham, que tipos de movimentos determinam ecomo se relacionam.


Subject(s)
Anatomy , Mandible , Maxilla , Denture, Complete , Dental Prosthesis Retention
13.
Rev. Salusvita (Online) ; 27(1): 111-124, 2008. tab
Article in Portuguese | LILACS | ID: lil-562321

ABSTRACT

O sucesso em longo prazo das reabilitações implanto-suportadas advém em grande parte de um rigoroso planejamento cirúrgico protético realizado previamente ao procedimento cirúrgico. Assim, o objetivo deste artigo foi realizar uma revisão de literatura a fim de abordar os principais pontos durante um planejamento cirúrgico protético de reabilitações utilizando implantes. Para isso, utilizou-se o indexador MEDLINE, sendo selecionados 28 artigos originais e atuais relacionados ao tema. A partir da literatura consultada, concluiu-se que um adequado planejamento é muito importante para a obtenção do sucesso estético-funcional para reabilitação com prótese sobre implante, sendo de fundamental importância a inter-relação do cirurgião com o protesista.


Longitudinal success in implant-supported rehabilitations is based on a precise surgical-prosthetic planning done previously to the surgical procedure. So, the objective of this study was to make aliterature review about the principal aspects during the surgicalprostheticplanning. For this, the MEDLINE indicator was used, being selected 28 actual and original articles related to the theme.Through the consulted literature it was concluded that an adequate planning is very important to obtain aesthetic-functional success in rehabilitations with implants, and that interaction between surgeon and prosthodontistis fundamental.


Subject(s)
Humans , Male , Female , Dental Implants , Dental Prosthesis , Dentures , Dental Prosthesis Design
14.
Rev. Salusvita (Online) ; 27(2): 135-146, 2008.
Article in Portuguese | LILACS | ID: lil-562307

ABSTRACT

A perda dental e seus problemas decorrentes são situações prevalentes na velhice. As mobilidades dentárias e retrações gengivais são sinais típicos de alterações dos tecidos gengivo periodontais, acometendo com maior freqüência o paciente geriátrico, pelo próprio processo de envelhecimento ou pela falta de medidas preventivas. Dessa forma, esse trabalho teve por objetivo abordar os principais aspectos periodontais do paciente geriátrico, reconhecendo as suas alterações fisiológicas e as necessidades específicas de higienização e fisioterapia oral. Verificou-se através da literatura que a demanda de serviços odontológicos para idosos tem aumentado, devendo o cirurgião dentista deve estar apto a atender esse tipo de paciente, saber reconhecer as principais alterações bucais e orientar e tratar essas manifestações. A prevenção e o controle da formação da placa bacteriana dental são as medidas mais importantes para a manutenção da saúde periodontal.


The dental loss and the problems consequence of this are commonsituations in the elderly patient. The periodontal tissues generally show aging evidences during the natural process of development.The dental mobility and gingival recession are typical pathologies of periodontal tissues, to happen often in elderly patient, by the same aging process or the lack of prevent dental care. Thus, the purpose of this study was management of the periodontal aspects in the elderly patient, recognizing physiologic alterations and the specific care of hygienic and oral physiotherapy. Through the literature it was identified that the demand of dental services for aging have to increase. However, the dentist have to be able to attend this kind of patient recognize the main buccal alterations, guide to patient and treatment of oral manifestations. The prevention and control of dental bacterial plaque are the most important principles for the maintenance of the periodontal health.


Subject(s)
Humans , Male , Female , Aged , Aged , Geriatric Dentistry , Oral Health , Patient Care , Periodontal Diseases
15.
Odontol. clín.-cient ; 6(3): 223-227, jul.-set. 2007.
Article in Portuguese | LILACS, BBO | ID: lil-500991

ABSTRACT

A idade trás algumas mudanças nas funções biológicas bem como um decréscimo da capacidade produtiva e reprodutiva. Essas mudanças são acompanhadas de alterações psicológicas no modo pelo qual o indivíduo constrói o mundo ao redor e sua percepção interna. Dessa forma, os idosos tem dificuldade de aceitar algumas das evoluções do mundo e suas transformações inerentes. É comum observar em pessoas mais velhas a ausência de cuidados com a saúde e com o corpo, o que mostra uma auto-estima baixa e um sentimento antecipado do fim de sua vida. Por esse motivo, cuidar de idosos requer enxergar além do prognóstico e preferências para entender a dinâmica de suas expectativas. Dessa forma, esse artigo tem por objetivo fazer uma abordagem psicanalítica quanto ao processo de envelhecimento, com o propósito de levar o cirurgião-dentista a uma melhor compreensão das caracterísitcas do paciente geriátrico, valorizando o conhecimento de suas particularidades, estreitando os laços com o paciente e facilitando, dessa forma, o atendimento odontológico. Para isso foi utilizado o indexador Medine database com o cruzamento dos termos geriatric and psicologia, e o indexador BBO com o termo geriatria. Percebe-se que é de fundamental importância que o profissional entenda o paciente idoso como um todo, suas características, condições fisiológicas e principalmente psicológicas. Desse modo, o cirurgião-dentista promove além da saúde bucal, a qualidade de vida do idoso, devolvendo-o ao convívio social e familiar, fazendo-o enxergar com olhos diferentes o mundo que os cerca, para que envelheçam de maneira mais saudável.


Subject(s)
Aged , Dentist-Patient Relations , Geriatric Dentistry , Health of the Elderly , Psychophysiology , Psychosomatic Medicine , Quality of Life
16.
Rev. odontol. UNESP ; 36(2): 189-192, abr.-jun. 2007.
Article in Portuguese | LILACS, BBO | ID: lil-529274

ABSTRACT

Este artigo descreve uma técnica alternativa para confecção de um espécime para teste de cisalhamento entre resina acrílica e dente artificial.


This article describes an alternative technique for fabricating a specimen for shear bond testing between acrylic resin and artificial teeth. The technique involves a special machine to embed the artificial tooth on which the acrylic resin is processed.


Subject(s)
Tooth, Artificial , Acrylic Resins , Shear Strength
17.
Ciênc. odontol. bras ; 10(2): 16-24, abr.-jun. 2007.
Article in English | LILACS, BBO | ID: lil-518110

ABSTRACT

The aim of this study was to evaluate the influence of the implants inclination on the accuracy of the working cast obtainedby two different pouring techniques. A metallic matrix containing two implants, positioned at 90 and 65 degreesin relation to the alveolar ridge, was submitted to the direct transfer impression technique. In CP group (conventionalpouring - n=10), the impressions were poured with dental stone type IV using the conventional technique. In EP group(experimental pouring - n=10), the analogs were embraced with latex tubes before the first pouring. After sixty minutes,these tubes were removed and the space was filled with the dental stone. The metallic matrix (control group) and thereplicas were evaluated regarding the implant/analog inclination and the vertical misfit between a framework and theimplants/analogs. The data were tabulated and analyzed using analysis of variance (ANOVA) and Tukey test at the 0.05level of significance. Regarding the analog inclination, both experimental groups differed statistically (p<0.05) from thecontrol group only in relation to the leaning analogs. Results demonstrated significant difference (p<0.05) between thecontrol group and the experimental groups when the reading of the vertical misfit was accomplished in the perpendicularimplant/analog with the retention screw in the leaning implant/analog and between the control group and the EP group in the opposite situation.Considering the inclination, perpendicular implants produced more accurate casts independentlyof the plaster pouring technique.


O objetivo deste estudo foi avaliar a influência da inclinação dos implantes na precisão do modelo de trabalho obtidoatravés de duas técnicas distintas de vazamento. Uma matriz metálica contendo dois implantes, posicionados a 90ºe a 65º em relação ao rebordo alveolar, foi submetida à técnica de moldagem de transferência direta. No grupo CP(vazamento convencional û n=10) os moldes foram vazados com gesso pedra tipo VI através da técnica convencional.No grupo EP (vazamento experimental û n=10) os análogos foram envolvidos com tubos de látex antes do primeirovazamento. Após sessenta minutos, os tubos foram removidos e o espaço foi preenchido com nova porção de gesso.A matriz metálica (grupo controle) e as réplicas foram avaliadas com relação à inclinação dos implantes/análogos eà desadaptação vertical entre uma supraestrutura e os implantes/análogos. Os dados foram tabulados e analisadospela análise de variância (ANOVA) e pelo teste de Tukey com nível de significância a 5%. Com relação à inclinaçãodos análogos, ambos os grupos experimentais exibiram diferença estatística (p<0.05) em relação ao grupo controleapenas para os análogos inclinados. Os resultados mostraram diferença significativa (p<0.05) entre o grupo controlee os grupos experimentais quando a desadaptação vertical foi observada no implante/análogo perpendicular com oparafuso de retenção localizado no implante/análogo inclinado e entre o grupo controle e o grupo EP na situaçãooposta. Considerando a inclinação, implantes perpendiculares produzem modelos mais precisos independentementeda técnica de vazamento do gesso.


Subject(s)
Prostheses and Implants , Dental Prosthesis, Implant-Supported , Calcium Sulfate , Dental Impression Technique
18.
Pesqui. bras. odontopediatria clín. integr ; 7(1): 83-88, jan.-abr. 2007.
Article in Portuguese | LILACS | ID: lil-526699

ABSTRACT

Introdução: Com o envelhecimento populacional, o número de enfermidades crônicas e degenerativas, próprias da velhice, surgirá com maior freqüência. Objetivo: Fazer uma revisão de literatura a fim de abordar as enfermidades que mais acometem os pacientes da terceira idade (desde as doenças crônicas até mesmo as doenças crônicas degenerativas). Para isso, será realizada uma descrição quanto o conceito e os sinais e sintomas das enfermidades observadas com maior freqüência nos pacientes idosos que serão depressão, estresse, perda da memória, aterosclerose, osteoporose, artrite reumatóide e desordem temporomandibular, hipertensão arterial, doenças vasculares, doenças cardíacas, obesidade, diabetes mellitus, incontinência urinária, distúrbios auditivos e visuais, doença de Parkinson e ainda a doença de Alzheimer. Conclusão: Baseado na revisão de literatura, concluí-se que, não só os profissionais da saúde, bem como todos aqueles que lidam com os idosos de uma forma geral, devem ter a preocupação de tratá-lo com maior atenção, paciência e perseverança, a ponto de minimizar as limitações que cada um apresenta.


Introduction: With the populational aging, a number of chronic and degenerative illnesses, common in the old age, will present more and more frequently.Purpose: To perform a literature review that addresses the most commonly manifested illnesses in third-age patients (ranging fromchronic illnesses up to degenerative chronic illnesses). For suchpurpose, a description will be made regarding the concept and signs and symptoms of the most frequently observed illnesses in elderly patients, namely depression, stress, loss of memory,atherosclerosis, osteoporosis, rheumatoid arthritis,temporomandibular disorders, hypertension, vascular diseases,cardiac diseases, obesity, diabetes mellitus, urinary incontinence,hearing and visual disturbances, Parkinson's disease andAlzheimer's disease.Conclusions: Based on the review of literature, it may be concluded that not only health professionals, but all individuals that deal with elderly people in general should treat them with in a more attentive, patient, perseverant manner in order to minimize the limitations that each individual presents.


Subject(s)
Alzheimer Disease , Diabetes Mellitus , Geriatric Dentistry , Aged/psychology , Parkinson Disease , Patient Care
19.
Ciênc. odontol. bras ; 10(1): 40-46, jan.-mar. 2007.
Article in Portuguese | LILACS, BBO | ID: lil-518101

ABSTRACT

A proposta desse estudo foi avaliar a rugosidade de resinas acrílicas próprias para confecção de próteses oculares, submetidas a dois diferentes métodos de inclusão e polimento, antes e após 60 dias de armazenagem. Foram confeccionados 24 corpos-de-prova, obtidos a partir de discos em resina acrílica incolor confeccionados em prensa semi-automática. Osdiscos foram incluídos em muflas próprias para microondas, utilizando dois diferentes tipos de materiais para revestimento, gesso especial e silicone de condensação. Após a presa final do gesso, as muflas foram abertas, os discos retirados e a resina prensada e polimerizada em forno microondas. Após o resfriamento natural das muflas, os corpos-de-prova foram desincluídos e submetidos ao acabamento e polimento. Dos 24 corpos-de-prova obtidos, 12 receberam polimento mecânicoe restante polimento químico. Os corpos-de-prova foram submetidos ao teste de rugosidade de superfície, antes e apósum período de armazenagem de 60 dias, utilizando um rugosímetro digital portátil modelo RP100 (Tonka Sul AmericanaLtda, Brasil). Para cada corpo-de-prova foram realizadas 3 leituras que posteriormente foram transformadas em valores médios. Os resultados obtidos foram avaliados utilizando análise de variância seguido pelo teste de Tukey em nível de 5% de significância. Em todos os grupos houve um aumento na rugosidade superficial após 60 dias de armazenagem, porém estes valores só foram estatisticamente significantes para os corpos-de-prova polidos quimicamente. O grupo silicone proporcionou menores valores de rugosidade para os grupos quimicamente polidos. Independente do polimento empregado e do tempo de armazenagem, a inclusão com gesso proporcionou maiores valores de rugosidade superficial.


Subject(s)
Acrylic Resins , Eye, Artificial
20.
Pesqui. bras. odontopediatria clín. integr ; 6(2): 207-212, Mai.-Ago.2006.
Article in Portuguese | LILACS, BBO | ID: biblio-853713

ABSTRACT

A população mundial está envelhecendo,principalmente nos países em desenvolvimento como o Brasil.Com o envelhecimento populacional, o número de patologias,próprias da velhice, surgirá com maior freqüência. Dentre essas doenças podemos citar a de Alzheimer, uma demência irreversível, na qual tem sido associado à idade, à doença cérebro vascular, ao infarto do miocárdio, a defeitos imunológicos e a fatores genéticos (síndrome de Down). Sabe-se que com a progressão da demência, os pacientes apresentam dificuldade de higienização oral, principalmente porque os portadores de doença de Alzheimer ficam com as funções cognitivas e motoras diminuídas. Seus portadores são pacientes que demandam estratégias específicas para que o cirurgião dentista possa atendê-lo sem maior dificuldade.Objetivo: Fazer uma revisão de literatura sobre a relação entre a odontogeriatria e a doença de Alzheimer, enfocando as características dos pacientes com esse tipo de demência e os cuidados para com eles. Para isso, foi utilizando o indexador Medline database, no período de 1972 a 2006, com o cruzamento dos termos alzheimer disease and dentistry e o indexador BBO, no período de 1987 a 2004, com o termogeriatria. Conclusão: Os estudos, de uma forma geral,indicaram que os pacientes portadores dessa doença apresentam maiores problemas de saúde bucal em relação aos não portadores


Subject(s)
Humans , Aged , Patient Care , Alzheimer Disease , Geriatric Dentistry , Oral Health
SELECTION OF CITATIONS
SEARCH DETAIL